Page view 21
Wall Mounting Kit
Condensing Pool Heater
19
22/12/08
Fig. 10.4
Fig. 10.3
476
376
940
170
46
HEATER
OUTLINE
TOP WALL
MOUNTING
BRACKET
HORIZONTAL
WALL
TERMINAL
CORE DRILL
POSITION
BOTTOM WALL
MOUNTING
BRACKET (FITTED TO
HEATER BEFORE
WALL HUNG)
FLOOR
DRILL HOLES AFTER
HEATER HAS BEEN
WALL HUNG
5MM STUD (2 PLC'S)
HEATER CABINET HEIGHT
HEATER CABINET WIDTH
80
REQUIRED CLEARANCE
Overview
The Genie 35 and 50 models can be wall hung
using the Wall Mounting Kit.
Kit Part Code: MBWMK35/50
Instructions
Select a suitable wall and position to mount the
Heater. (Note the Heater weighs 40kg.)
Screw the Top Wall Mounting Bracket level to the
wall. (Fig 10.4)
Attach the Top Handle Bracket to the rear of the
Heater by using the 3 M4 screws supplied.
(Fig 10.5)
Attach the Bottom Wall Mounting Bracket to the
rear of the Heater by using the existing 3 gold
screws that fix the base to rear panel.(Fig 10.5)
Hang the Heater on Top Wall Mounting Bracket
locating it on the two 5mm studs.
With the Heater now in position drill and screw
the Bottom Wall Mounting Bracket to the wall.See
(Fig 10.4)